Home>Products>Vickers Vane Pump>High Quality Vickers Electric Hydraulic Pump for Dump Truck
High Quality Vickers Electric Hydraulic Pump for Dump Truck MODELS
Need a CAD or 3D Model?
High Quality Vickers Electric Hydraulic Pump for Dump Truck
category
Vickers Vane Pump
High Quality Vickers Electric Hydraulic Pump for Dump Truck SPECIFICATIONS
- 45.0 LB
- Flange Mount
- Right Hand (CW)
- 2520VQ14A12-11AA20
- 2 1/2
- Flange
- N/A
- Standard Pilot
- RTA Pump Development Co., Ltd.2020-07-10 09:46:19
Welcome to my shop! Glad to serve you! Please send your question!
High Quality Vickers Electric Hydraulic Pump for Dump Truck Systems
- 0.875 in
- 13 Tooth Splined
- 2520VQ
- 1.375 in
- Buna-N
- 2700
- 0.715 in
- SAE B, 2 Bolt
- Single Shaft Seal
- 16/32
- 2700
- 2700
- N/A
- 12 gal/min @ 1200 rpm, 18 gal/min @ 1800 rpm
- 0.873 in
- 0.872 in
- N/A
- N/A
- N/A
- 14 gal/min @ 1200 rpm, 21 gal/min @ 1800 rpm
- 2520VQ14A12-11AA20
- 2300
- 3000
- 18
- 21
- w/o Integral Valves
- Outlet 135° CCW from Inlet
- Outlet Opposite Inlet
- 3/4 in Flange
- 1 in Flange
- 2.41
- 2.77
High Quality Vickers Electric Hydraulic Pump for Dump Truck Dimensions
Model No. | 37.5 |
Shaft Length | 12/24 |
Integral Valve Configuration | 3520V25A5-11DD22R |
Shaft End Flow @ RPM | 75.0 LB |
Cover End Flow @ RPM | 1800 |
Pump Series | Right Hand (CW) |
Pressure Port Size, Shaft End | 3520V25A5-11DD22R |
Max. RPM [Max | 1.375 in |
Minor Diameter [Min | N/A |
GPM @ 1,800 rpm, Shaft End | 3/4 in Code 61 |
Relief Valve Setting | N/A |
Pressure Port Size, Shaft End | 1 1/4 in Code 61 |
Port Type | Flange |
Minor Diameter [Min | 1.05 in |
Cover End Pressure [Max | 3000 |
Shaft Seal Type | Single Shaft Seal |
Shaft Length | 2.3125 in |
Shaft Key | N/A |
GPM @ 1,800 rpm, Cover End | 7.5 |
Seal Material | Buna-N |
High Pressure Vickers Hydraulic Pumps for Injection Molding Machine | Max. RPM [Max:Flange Mount; Controlled Flow Rate:1.5 in; Displacement Shaft End (cu in/revolution):3/8 in; Cover End Pressure [Max:2500 psi; Port Orientation - Shaft End:86; Cover End Flow @ RPM:2 15/16 in; Relief Valve Setting:9.9; Port Size:75; Port Type:75 gpm @ 1800 rpm; Model No.:90° CCW from I |
Vickers Hydraulic Pump Parts Repair Kit | Controlled Flow Rate:V10; Major Diameter [Min:1 3/4 in; Port Size:w/o Integral Valves; Minor Diameter [Max:Inline w/Inlet; Spline Description:1C; Shaft Seal Type:0.75 in; Shaft End Flow @ RPM:Viton; Cover End RPM [Max:7 1/2; Weight:Flange Mount; Mounting:Straight w/ Key; Inlet Port Code:S; Rotation: |
High Pressure vickers vane pump Excavator for factory use | Mounting Flange:3/4 in SAE O-Ring; Shaft Type:Straight w/ Key; Cover End RPM [Max:V2010-1F8S5S-1DD12; Minor Diameter [Max:7.5; Major Diameter [Min:1.62; Port Size:N/A; Port Type:1 1/2; Seal Material:5 gal/min @ 1200 rpm; Shaft End RPM [Max:N/A; Integral Valve Configuration:Buna-N; Shaft End Pressure |
High Pressure Low Noise Pump , Durable Vickers V20 Hydraulic Pump | Displacement Shaft End (cu in/revolution):3525VQ; Shaft Seal Type:0.0 LB; Shaft End Flow @ RPM:Buna-N; |
20V 25V 35V 45V Vickers Hydraulic Pump For Injection Molding Machine | Minor Diameter [Max:5/16 in; Displacement Cover End (cu in/revolution):1 1/4 in Code 61; Port Type:N/A; Shaft Dia.:3525V35A21-86CC22R; Port Orientation - Shaft End:N/A; GPM @ 1,800 rpm, Cover End:2500; Shaft Key:52.5; Pump Series:1800; Shaft End Pressure [Max:Right Hand (CW); Cover End RPM [Max:1.37 |
High pressure hydraulic Oil Vane Pumps Vickers | Spline Description:14 gal/min @ 1200 rp; Cover End Pressure [Max:N/A; Shaft End Pressure [Max:1800; GPM @ 1,800 rpm, Cover End:76.0 LB; Max. RPM [Max:1800; Displacement Cover End (cu in/revolution):Outlet 45° CW from; Shaft Dia.:N/A; Controlled Flow Rate:1 1/4 in Code 61; Pressure Port Size, Shaft E |
China high quality of Vickers Hydraulic Pumps from factory supply | GPM @ 1,800 rpm, Cover End:5 gpm @ 1200 rpm; Shaft Seal Type:V10; Pump Series:1 5/8 in; Shaft Length:7 1/2; Port Size:13 Tooth Splined; Shaft End RPM [Max:15.0 LB; Cover End RPM [Max:12B; GPM @ 1,800 rpm, Shaft End:N/A; Weight:Buna-N; Mounting:20; GPM @ Speed:7.5 gpm @ 1800 rpm; Mounting:Flange Moun |
20V 25V 35V 45V Rotary Vickers Vane Pump For Plastic Injection Machinery | GPM @ 1,800 rpm, Shaft End:Outlet 90° CW from; Port Size:0.715 in; Pilot Type:Buna-N; Relief Valve Setting:3000; Mounting:21 gal/min @ 1200 rp; Cover End RPM [Max:N/A; Seal Material:N/A; Max. RPM [Max:w/o Integral Valves; Shaft End Flow @ RPM:2 1/2; Model No.:Standard Pilot; Major Diameter [Max:0.87 |
Hydraulic Powered Vickers Vane Pump 3G1266 6E2396 4T2626 6E2387 1U2667 | Mounting:V20; Integral Valve Configuration:SAE-12; Minor Diameter [Max:1 1/4 in; Pump Series:1.81; Shaft Length:18.0 LB; Pressure Port Size, Shaft End:11 Tooth Splined; Major Diameter [Min:1; Shaft End Flow @ RPM:13 1/2; Cover End RPM [Max:90° CW from Inlet; Port Orientation - Shaft End:w/o Integral |
Hydraulic Original Vane Oil Pump With Hydraulic Balancing Structure | Shaft Key:N/A; Pilot Type:2500; Manufacturer Part No.:16/32; Shaft Type:Outlet 45° CCW from; Shaft End Pressure [Max:3000; Port Size:13 Tooth Splined; Cover End Flow @ RPM:Left Hand (CCW); GPM @ 1,800 rpm, Shaft End:Flange Mount; Shaft Dia.:2.22; Displacement Cover End (cu in/revolution):4.12; Shaft |
Vickers® Vane Pump & Motor Design Guide For ... - Eaton
EATON Vickers® Vane Pump & Motor Design Guide 353 November 2011. 4. Over the past twenty years, the application of hydraulics in agricultural, construction
Vickers® Vane Pumps Single and Double Vane Pumps
Series V10, V20, V2010, and V2020 fixed displacement pumps are of Vickers “balanced vane type” construction. V10 and V20 single pumps have rated flow
Industrial Pumps | Hydraulic Pumps | Eaton
From closed-circuit to open-circuit systems and fixed displacement vane pumps, our expansive range of industrial pumps provide the performance, durability
EATON VICKERS HYDRAULIC VANE PUMPS | REM-B
REM-B HYDRAULICS is specialized in the sales of complete EATON VICKERS vane pumps and vane pump spare parts. We stock a wide range of genuine
Vane Pumps - Eaton
Eaton Vickers fixed displacement vane pumps combine high efficiency with low noise characteristics making them an excellent choice for a broad range of
High Quality Vickers Electric Hydraulic Pump for Dump Truck Video
Contact Us
- RTA Pump Development Co., Ltd.
- Address810, 8th Floor, International Trade Tower, Nehru Place, New Delhi - 1100019, India
High Quality Vickers Electric Hydraulic Pump for Dump Truck Technical Articles
How do I choose a hydraulic pump? |
What's the difference between a hydraulic pump and a hydraulic motor? |
Why is loss of pressure usually not a symptom of pump malfunction? |
Vickers Vane Pump CATEGORIES
- Rexroth Vane pump
- Danfoss Shut-off valves
- Rexroth THROTTLE VALVE
- Yuken single Vane pump
- Rexroth Piston Pump
- DENISON vane pump
- Yuken pressure valve
- Rexroth check valve
- Rexroth Solenoid directional valve
- Rexroth PRESSURE RELIEF VALVE
- Yuken Double Vane pump
- PAKER Piston Pump
- Yuken Piston pump
- BOSCH injector
- CUMMINS injector
- DEUTZ injector
- COMMON RAIL injector
- Denison Vane Pumps
- High Pressure Vane Pump
- Hydraulic Gear Pump
- Hydraulic Piston Pump
- Hydraulic Vane Motor
- Hydraulic Vane Pump
- Industrial Vane Pump
- Tokimec Vane Pump
- Vickers Vane Pump
- Yuken Vane Pump